Ultrasonic flow meter

SONICO® EDGE
Properties:
  1. Very low starting flow: 5 l/h
  2. Highest measuring range: R1000
  3. Volume resolution: 0.1 l/h
  4. Low pressure loss: <0.09 bar
  5. 4 Hz measuring sampling rate in test and operation mode
  6. Homogeneous measuring channel
  7. Dry sensors without any sensor pockets
  8. No flow straightener
  9. Can be installed in all directions and mounting positions
  10. Can be installed directly after 90° bends, valves and pumps
  11. Automatic detection of flow direction
  12. IP68
  13. Approved firmware security and update procedure according to WELMEC 7.2 European Legal Metrology
  14. 3 x independent NFC communication interfaces for local and wide area connectivity
Applications
  1. Water measurement, e.g. potable and waste water
  2. Utility water e.g.reservoirs and pumping stations, etc.
  3. Industrial applications e.g process control and measruements
DOWNLOADS
LINKS

KATflow 100

Stationary Clamp-On ultrasonic flow meter

Features
  1. Non-contact flow and heat quantity measurement in one measurement path each
  2. Pipe diameter range from 10 mm to 3000 mm
  3. Temperature range for sensors -30 °C to +80 °C
  4. Sturdy unit with LCD display and five-key keypad
  5. Robust IP 66 aluminium enclosure
  6. Weight 750 g
  7. Accuracy volume flow: ± 1 – 3 % of measured value (depending on application)
  8. Flow velocity range: 0.01 – 25 m/s
  9. Turn down ratio: 1/100 (equivalent to 0,25 – 25 m/s)
  10. Gaseous and solid content of liquid media < 10 % of volume
Benefits
  1. Low cost of ownership
  2. Innovative installation wizard for quick and intuitive programming
  3. Modular process output options icluding Modbus RTU (RS 485)
  4. PT100 inputs for heat quantity (thermal energy) measurement
  5. Bi-directional measurement with totaliser function
Applications
  1. Water and wastewater measurements
  2. Automated process control
  3. Replacement of electromagnetic flowmeters
  4. Monitoring and controlling of Heating, Ventilation and Air-Conditioning (HVAC) systems
  5. Cost-effective solution for large scale projects
DOWNLOADS

FT-S (Feedthrough)

Technical specifications
  1. Frequency: 1 MHz
  2. Beam width: 5° (-3dB)
  3. Configuration: IEC41 / ASME PTC 18
  4. Pipe diameter: 0.1 m to 2 m
  5. Mounting: welding socket or thread
  6. Pressure rate: 20 bar *
  7. Material: stainless steel
  8. Cable: twisted pair with shield
  9. Operating temperature: 0° to +40°C (up to +150 °C on request)
  10. Dimensions: Ø 1″, length: 293 mm
  11. Installation: incl. fixing device, ball valve and welding socket.
    Pipe needs to be dewatered only for the time of initial installation. Designed to allow removal of the entire transducer for repair, replacement or cleaning without the need to dewater the pipe lation.

*) other ranges upon request

Related products

Ductus S

Time of flight system with digital signal processing

Technical specifications
  1. Acoustic paths: 1 to 10 (more upon request)
  2. Range: ± 20 m/s (bidirectional)
  3. Accuracy Q: up to ± 0.15 % (10 paths)
  4. Repeatability: < ± 0.02 %
  5. Zero Stability: < 1 mm/s
  6. Communication: RS-485, Modbus RTU/TCP, Wireless LAN, Ethernet 10/100 Mbps, 4G (LTE) / 3G (HSPA+) / 2G
  7. Inputs: max. 4 x 4-20 mA, 2 x digital
  8. Outputs: max. 4 x 4-20 mA, 4 x relay, 2 x pulse
  9. Power supply: 9-36 V DC or 100-240 V AC (50/60 Hz)
  10. Approval: IP65 (NEMA 4)
  11. Enclosure: ABS, wall mounted
DOWNLOADS
Related products

CO-L (Clamp-On)

Technical specifications
  1. Pipe Diameter: 0.4 m to 15 m
  2. Pipe wall thickness: up to 100 mm (steel, plastic, glass fiber)
  3. Accuracy velocity: up to ± 0.5 % of reading
  4. Frequency: 200 kHz
  5. Beam width: 8° (-3dB)
  6. Material: stainless steel, polyamide
  7. Operating temperature: -20 °C to +60 °C
  8. Dimensions: 270 x 115 x 100 mm (L x W x H)
  9. Installation: from the outside of the pipe
Related products

FT-L1000 (Feedthrough)

Technical specifications
  1. Frequency: 1 MHz
  2. Beam width: 10° (-3dB)
  3. Configuration: IEC41 / ASME PTC 18
  4. Pipe diameter: 0.3 m to 5 m
  5. Mounting: welding socket or thread
  6. Pressure rate: 60 bar *
  7. Material: stainless steel
  8. Cable: twisted pair with shield
  9. Operating temperature: 0° to 40°C
  10. Dimensions: Ø 1 1/2″, Length: 186 mm
  11. Installation: removal of the transducer for repair, replacement or cleaning by means of a special jacking tool.

*) other ranges upon request

Related products

Ductus M

Time of flight system with digital signal processing

Technical specifications
  1. Acoustic paths: 1 to 8
  2. Accuracy: up to ± 0.5 % (8 paths)
  3. Range: 0 to ± 20 m/s (bidirectional)
  4. Pipe diameter: > 3000 mm
  5. Display: 4 lines, 20 characters
  6. Windows 10 operating system
  7. Configuration and parameter setup with integrated software package
  8. Data logger: internal, sampling interval user selectable
  9. Interfaces: VGA (1024*768), PS/2 for external mouse, keyboard, 4x USB, 2x RJ-45
  10. Communication: 2 x RS-232, FTP, Modbus TCP (optional)
  11. Inputs: max. 8 x 4-20 mA
  12. Outputs: max. 4 x 4-20 mA, 2 x relay, 2 x pulse
  13. Power supply: 24 V DC
  14. Battery backup: integrated, 2 Ah
  15. Protection Class: IP65 (NEMA 4)
  16. Enclosure: powder-coated sheet steel, wall mounted
DOWNLOADS